{"product_id":"dimlux-maxi-controller-v1-2-co2-sensor","title":"Dimlux Maxi Controller V1.2 and CO2 Sensor Kit","description":"\u003ch2\u003eRead CO2 at the Canopy and Dose It Automatically\u003c\/h2\u003e\u003cp\u003eThis pairs the \u003cstrong\u003eDimlux Maxi Controller V1.2\u003c\/strong\u003e with the \u003cstrong\u003eDimlux CO₂ Sensor\u003c\/strong\u003e and a \u003cstrong\u003e10 metre cable\u003c\/strong\u003e. The sensor reads the \u003cstrong\u003eCO₂ value beside the plant\u003c\/strong\u003e rather than at the wall, and doses through its own switched power point when levels drop. The controller handles lighting, heaters and humidifiers, and \u003cstrong\u003edims the lamps automatically\u003c\/strong\u003e once temperature passes a level you set.\u003c\/p\u003e\u003ch3\u003eWhat’s Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimlux Maxi Controller V1.2\u003c\/strong\u003e – central control for lighting, heating, humidity and CO₂\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimlux CO₂ Sensor\u003c\/strong\u003e – canopy-level measurement with a light cell and switched outlet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 metre sensor cable\u003c\/strong\u003e with data plug\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate canopy-level readings\u003c\/strong\u003e, so CO₂ is dosed only when genuinely needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in light cell\u003c\/strong\u003e senses the day cycle, so \u003cstrong\u003eno CO₂ is dosed at night\u003c\/strong\u003e and nothing is wasted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with the PT camera and temperature sensor\u003c\/strong\u003e, pausing dosing if plant temperature is too high\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic lamp dimming\u003c\/strong\u003e when the room exceeds your maximum temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlugs straight into a wall socket\u003c\/strong\u003e with no relay, time delay unit or time switch in between\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhy Is Your CO2 Enrichment Not Showing in the Yield?\u003c\/h3\u003e\u003cp\u003eDosing blind is usually the reason. Gas released without a reading at the canopy either falls short or gets vented, and dosing at night or into a hot room burns money while stomata stay shut. Poor nutrient uptake, slow growth and low yields follow. Measuring where the leaves are turns CO₂ into growth.\u003c\/p\u003e\u003ch3\u003eHow to Use\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHang the sensor at plant height\u003c\/strong\u003e where light falls on the light cell – that is what tells it daytime has begun\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower the sensor\u003c\/strong\u003e from a wall socket and run the data plug into the \u003cstrong\u003e\"CO₂\" slot\u003c\/strong\u003e on the controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect your source:\u003c\/strong\u003e a CO₂ generator, or a pressure-reducing valve with a cold CO₂ valve, plugs into the sensor’s power point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet your target\u003c\/strong\u003e CO₂ level and a maximum room temperature so lamps dim before the room runs away\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"hcs-specs\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController:\u003c\/strong\u003e Dimlux Maxi Controller V1.2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor:\u003c\/strong\u003e Dimlux CO₂ Sensor with integrated light cell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 10 metres, data plug to \"CO₂\" slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e Lighting, CO₂ dosing, heaters, humidifiers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNight Dosing:\u003c\/strong\u003e Disabled automatically via light cell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp Dimming:\u003c\/strong\u003e Automatic on ambient temperature threshold\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Power:\u003c\/strong\u003e Mains wall socket, switched outlet for CO₂ generator or regulator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Required:\u003c\/strong\u003e No – connects directly without relay, time delay or time switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Dimlux","offers":[{"title":"Default Title","offer_id":53445708841226,"sku":null,"price":565.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/7127\/5786\/files\/co2-dimlux-maxi-controller-v1-2-co2-sensor-29630176297144.jpg?v=1785325052","url":"https:\/\/hydrocropshop.co.uk\/products\/dimlux-maxi-controller-v1-2-co2-sensor","provider":"Hydro Crop Shop","version":"1.0","type":"link"}